Passiv houses systems
Rihter developed two new construction systems to meet the passive house standard.
Features of the STANDARD PLUS PASIV System:
System thickness:
- Outer walls 490 mm
- Inner walls 149 mm
- Ceilings 270 mm
- Roof 617 mm
Outer wall cross-section (description from outside to inside):
- Parapermeable facade rough-cast
- Stone wool FP-PL 160 mm
- Gypsum fibreboard 15 mm
- Wooden construction 220 mm
- Insulation DP-3 in a wooden construction 220mm
- OSB plate 15m m
- Installations flat battens 60mm
- Insulation DP-3 in a wooden construction 60mm
- Plasterboard fire-proof plate (GKF) 15 mm
Advantages of the Standard plus pasiv system:
- Maintains and upgrades the features of the Standard plus system and meets the requirements for the construction of passive houses and other buildings
Heat transfer:
-
Outer walls U=0,095W/m2K
- Roof U=0,09 w/m2K
Features of the NATURA PASIV System
System thickness:
- Outer walls 490 mm
- Inner walls 149 mm
- Ceilings 270 mm
- Roof 613 mm
Outer wall cross-section (description from outside to inside):
- Parapermeable facade rough-cast
- Facade wood fibreboard 160 mm
- Gypsum fibreboard 15 mm
- Wooden construction 220 mm
- Insulation (light wooden fiber plate) 260 mm
- OSB plate 15m
- Installations flat battens 60mm
- Insulation DP-3 in a wooden construction 60mm
- Installations wood fibreboard 60mm
- Plasterboard fire-proof plate (GKF) 15 mm
Advantages of Standard Natura pasiv:
Heat transfer:
- Outer walls U=0,10 W/m2K
- Roof U=0,10 w/m2K